Click here to go to 
AngloINFO Normandy's front page
AngloINFO

· Global Home

· About AngloINFO

· AngloINFO News

· Contact

· Corporate

· Franchising

· Privacy Policy

La Bigottiere
Highly experienced, reliable, registered & insured English builder based in Orne. All Renovation & Restoration works undertaken - woodwork, plastering, plumbing, electrical, tiling and colombage. Also covers Calvados, Manche and Mayenne. Find out more...
DeVille Property Services
Specialist renovation & modernisation builder offering a full service including Septic Tanks, Roofing, Kitchens & Bathrooms, Electrics and Plumbing. Fully insured. Based in Mesnil Clinchamps (14) and serving Manche, Calvados & Orne. Find out more...
Steve Davidge Groundworks
Fosse Septique installed to DTU 64.1 Regs. CITB City & Guilds. French ANOFAB certificate for Assainissement Autonome. All machine work undertaken. All services laid. Free quotes and very competitive prices. Manche (50). Contact Steve or Sue. Find out more...
Normandy Local Reference INFOrmation
Share Share | Print Print
INFOrmation

The French Domestic Electrical System

The basics on French house wiring and how it compares to home electrics in the United Kingdom.

This INFOrmation Page is specifically for readers from the United Kingdom or those familiar with domestic electrical wiring in the UK.

Note: If you are not skilled and experienced with electrical wiring, contact a local professional. The official French specifications for domestic wiring are complicated and designed to be used by registered professionals with their specific equipment. (Qualified, registered electricians receive details and updates of the regulations). 

For simple domestic electrics: look for a “how to” guide at a bricomarché - hardware or DIY shops. 

The System

For those familiar with UK electrics, the French home electrical system is very unusual. The majority of the fittings, cabling and methods used in the UK cannot be applied to the wiring of a French house. 

The principle of the French electrical system is one of spurs, not of a ring main (as used in the UK). Each mains spur for sockets can carry a maximum of 16 amps at 220 volts (approximately 3,500 watts). Under normal application, there is a limit of five single or double sockets per spur.

Note: For Electric Heaters there is a maximum of one per spur and this must go back to the fuse box.

This is wired in using 2.5mm cable, which must be carried in conduit (or double insulated, including the earth cable).

Note: UK CE-marked twin-and-earth cable does not comply with French specifications. Neither do UK three-pin plugs. The use of either is likely to invalidate your French insurance and will not pass inspection for the Consuel (this normally takes place before the supply is connected by EDF.)

There are specific spurs for specific home appliances, such as the washing machine and cooker. A washing machine or dishwasher spur is at 20 amps, and a cooker spur is at 32 amps. Cable sizes depend on the length of the runs involved.

When applied in the kitchen, you can very quickly have spurs running everywhere. For example, a normal UK-spec kettle and a dishwasher cannot go on the same circuit.

You also have a separate 20amp spur for the hot water tank (ballon) which – should you opt for the French equivalent of Economy 7, the heures creuses – will be wired through an automatic three-way switch, which normally operates the hot water when the electricity is available at the lowest rate. (Generally, EDF will change your meter free of charge if you opt for the heures creuses and you can select various options for running appliances in the cheaper hours.) 

Lighting circuits are also wired on spurs, with a rating of 10 amps using 1.5mm double-insulated cable (normally individual wires in conduit). So again, UK CE-marked cable will not be accepted by inspectors, as the earth is not double-insulated.

The main fuse box is not the same as a UK box, which groups the neutrals together. In France each breaker has a live and neutral connection. The MCB is bi-polar - normally 45 amp, 500 ma.

Note: If you are renovating an older property, you could well find that the feed into the house is three-phase, as are the meter and the main distribution board. Do NOT try to wire the whole house off one phase - for example: every time you switch on the kettle you will blow the main feed.

Information correct as at April 2005

Further Information

Page prepared by Renov 2000
Bilingual Renovation & Electrics Service (Brittany)
Tel: 02 96 86 09 43 e-mail 
  www.renovation2000.com

 

Do you have a suggestion to improve this page? click here...
myAngloINFO

· Sign in

· Become a member NOW!


Stay INFOrmed! with our weekly newsletter.

Related Categories
Today
This week's VO movies
The English-language Cinema page has been updated with the next seven days' movies.
Winter Sales Start
Soldes d'hiver 2009 start today in all regions and continue to 10 February.

^ Top of Page ^


Page generated at 22:31; Wednesday 7 January, 2009
Copyright © 2000-2009 AngloINFO Limited. All rights reserved. Privacy Policy, Terms of Use, About, Advertising, Contact.
AngloINFO: Everyday life in France, in English · la vie quotidienne en France, en anglais

Find out more about AngloINFO in France...